J Appl Biomed 14:315-319, 2016 | DOI: 10.1016/j.jab.2016.05.003

Colorimetric sensor based on bubble wrap and camera phone for glucose determination

Pavla Martinkova, Miroslav Pohanka*
Faculty of Military Health Sciences, University of Defense, Brno, Trebesska 1575, 50001 Hradec Kralove, Czech Republic

Glucose is a typical marker of diabetes mellitus but it corresponds also with metabolic syndrome, immune disorders and some types of poisoning. Hence fast, low cost and simple method for its determination is required. Bubble wrap, cheap and available material, was used for immobilization of glucose oxidase (GOx) and peroxidase (POx), the enzymes necessary for colorimetric determination of glucose. Method is based on reaction of enzymes (immobilized in sol-gel membrane inside the bubbles) with substrates glucose and o-phenylenediamine dihydrochloride (o-PD) providing intensive coloration. The color change can be easily tracked by phone integrated camera. Color intensity expressed in red-green-blue (RGB) color model was used for displaying of photos and for gaining numeric data representing concentrations of glucose. The assay exerted good correlation of color intensity with the concentration of glucose, adequately low limit of detection (750 mmol/l) for glucose blood assay, no influence of interferents or matrix substances and by sufficient long term stability of sol-gel membrane. The sensor was found as low-cost simple way to analyze glucose blood levels with promising prospects in the field of portable devices.

Keywords: Biosensor; Glycaemia bubble wrap; Camera phone; Sol-gel; Glucose oxidase; Peroxidase

Received: February 22, 2016; Revised: May 11, 2016; Accepted: May 18, 2016; Published: November 1, 2016  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Martinkova P, Pohanka M. Colorimetric sensor based on bubble wrap and camera phone for glucose determination. J Appl Biomed. 2016;14(4):315-319. doi: 10.1016/j.jab.2016.05.003.
Download citation

References

  1. Akhtar, M.N., Sulong, A.B., Ahmad, M., Khan, M.A., Ali, A., Islam, M.U., 2016. Impacts of Gd-Ce on the structural: morphological and magnetic properties of garnet nanocrystalline ferrites synthesized via sol-gel route. J. Alloys Compd. 660, 486- 495. Go to original source...
  2. Brutsaert, E., Carey, M., Zonszein, J., 2014. The clinical impact of inpatient hypoglycemia. J. Diabetes Complicat. 28, 565-572. Go to original source... Go to PubMed...
  3. Bwambok, K.D., Christodouleas, D.C., Morin, S.A., Lange, H., Phillips, S.T., Whitesides, G.M., 2014. Adaptive use of bubble wrap for storing liquid samples and performing analytical assays. Anal. Chem. 86, 7478-7485. Go to original source... Go to PubMed...
  4. Chuen, H.J., Park, Y.M., Han, Y.D., Jang, Y.H., Yoon, H.C., 2014. Paper-based glucose biosensing system utilizinga smartphone as a signal reader. BioChip J. 8, 218- 226. Go to original source...
  5. Clark Jr., L.C., Lyons, C., 1962. Electrode system for continuous monitoring in cardiovascular surgery. Ann. N. Y. Acad. Sci. 102, 29-45. Go to original source... Go to PubMed...
  6. Cryer, P.E., 2007. Hypoglycemia, functional brain failure, and brain death. J. Clin. Invest. 117, 868-870. Go to original source... Go to PubMed...
  7. Deng, H., Teo, A.K.L., Gao, Z., 2014. An interference-free glucose biosensor based on a novel low potentialredox polymer mediator. Sens. Actuat. B 191, 522-528. Go to original source...
  8. Golden, S.H., Sapir, T., 2012. Methods for Insulin delivery and glucose monitoring in diabetes: summary of a comparative effectiveness review. J. Manag. Care Pharm. 18, S1-S17. Go to original source... Go to PubMed...
  9. Harris, J.M., Reyes, C., Lopez, G.P., 2013. Common causes of glucose oxidase instability in in vivo biosensing: a brief review. J. Diabetes Sci. Technol. 7, 1030- 1038. Go to original source... Go to PubMed...
  10. Ho, M.L., Wang, J.C., Wang, T.Y., Lin, C.Y., Zhu, J.F., Chen, Y.A., Chen, T.C., 2014. The construction of glucose biosensor based on crystalline iridium(III)-containing coordination polymers with fiber-optic detection. Sens. Actuators B 190, 479- 485. Go to original source...
  11. Homma, T., Ichimura, T., Kondo, M., Kuwahara, T., Shimomura, M., 2014. Covalent immobilization of glucose oxidase on the film prepared by electrochemical polymerization of N-phenylglycine for amperometric glucose sensing. Eur. Polym. J. 51, 130-135. Go to original source...
  12. Islam, S., Bidin, N., Riaz, S., Naseem, S., Marsin, F.M., 2016. Correlation between structural and optical properties of surfactant assisted sol-gel based mesoporous SiO2-TiO2 hybrid nanoparticles for pH sensing/optochemical sensor. Sens. Actuat. B 225, 66-73. Go to original source...
  13. Kumar, A., Malhotra, R., Malhotra, B.D., Grover, S.K., 2000. Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film. Anal. Chim. Acta 414, 43-50. Go to original source...
  14. Lu, Y., Shi, W., Qin, J., Lin, B., 2009. Low cost: portable detection of gold nanoparticlelabeled microfluidic immunoassay with camera cell phone. Electrophoresis 30, 579-582. Go to original source... Go to PubMed...
  15. Martinkova, P., Pohanka, M., 2015. Biosensors for blood glucose and diabetes diagnosis: evolution, construction and current status. Anal. Lett. 48, 2509-2532. Go to original source...
  16. Morin, L.G., Prox, J., 1973. Single glucose oxidase-peroxidase reagent for two-minute determination of serum glucose. Clin. Chem. 19, 956-962. Go to original source...
  17. Pohanka, M., Romanek, J., Pikula, J., 2012. Acute poisoning with sarin causes alteration in oxidative homeostasis and biochemical markers in Wistar rats. J. Appl. Biomed. 10, 187-193. Go to original source...
  18. Reddaiah, K., Madhusudana Reddy, T., 2014. Electrochemical biosensor based on silica sol-gel entrapment of horseradish peroxidase onto the carbon paste electrode toward the determination of 2-aminophenol in non-aqueous solvents: a voltammetric study. J. Mol. Liq. 196, 77-85. Go to original source...
  19. Sabzghabaee, M., Eizadi-Mood, N., Gheshlaghi, M., Adib, N., Safaeian, L., 2011. Is there a relationship between admission blood glucose level following acute poisoning and clinical outcome. Arch. Med. Sci. 1, 81-86. Go to original source... Go to PubMed...
  20. Singh, S., Singhal, R., Malhotra, B.D., 2007. Immobilization of cholesterol esterase and cholesterol oxidase onto sol-gel films for application to cholesterol biosensor. Anal. Chim. Acta 582, 335-343. Go to original source... Go to PubMed...
  21. Sonneville, R., Vanhorebeek, I., den Hertog, H.M., Chre'tien, F., Annane, D., Sharshar, T., Van den Berghe, G., 2015. Critical illness-induced dysglycemia and the brain. Intensive Care Med. 41, 192-202. Go to original source... Go to PubMed...
  22. Tonyushkina, K., Nichols, J.H., 2009. Glucose meters a review of technical challenges to obtaining accurate results. J. Diabetes Sci. Technol. 3, 971-980. Go to original source... Go to PubMed...
  23. Turkmen, E., Bas, S.Z., Gulce, H., Yildis, S., 2014. Glucose biosensor based on immobilization of glucose oxidase in electropolymerized poly(ophenylenediamine) film on platinum nanoparticles-polyvinylferrocenium modified electrode. Electrochim. Acta 123, 93-102. Go to original source...
  24. Turner, P.F., 2013. Biosensors: sense and sensibility. Chem. Soc. Rev. 42, 3184-3196. Go to original source... Go to PubMed...
  25. Zheng, X., Duan, C., Shen, J., Duan, X., 2015. Determination of reduced glutathione by spectrophotometry coupled with anti-interference compensation. Anal. Methods 7, 5005-5011. Go to original source...